Number | MODEL | POWER | VOLTAGE | FLOW – COLUMN PRESSURE | |||
HP | KW | VOLT | Qmax/Hmax | ||||
1 | 6SR30-4 | 5.5 | 4 | 380V | 10m³/47m | 25m³/35m | 40m³/10m |
2 | 6SR30-6 | 7.5 | 5.5 | 10m³/78m | 25m³/55m | 40m³/12m | |
3 | 6SR30-8 | 10 | 7.5 | 10m³/103m | 25m³/73m | 40m³/16m | |
4 | 6SR45-5 | 10 | 7.5 | 12m³/66m | 36m³/48m | 60m³/18m | |
5 | 6SR45-7 | 15 | 11 | 12m³/93m | 36m³/68m | 60m³/26m | |
6 | 6SR60-6 | 15 | 11 | 18m³/82m | 48m³/58m | 78m³/22m | |
7 | 6SR45-10 | 20 | 15 | 12m³/133m | 36m³/97m | 60m³/36m | |
8 | 6SR60-8 | 20 | 15 | 18m³/109m | 48m³/77m | 78m³/29m |
Flow – Column pressure
Applications
For water supply from wells or reservoirs.
For domestic use,for civil and industrial applications.
For garden and irrigation.
Operating conditions
Maxiumum fluid temperature up to +35ºC.
Maximum sand content : 0.25%.
Minimum well diameter : 6".
Motor and pump
Rewindable motor.
Single-phase : 220V- 240V /50Hz.
Three-phase : 380V – 415V /50Hz.
①Direct start(1 cable)
②Star-delta start (2 cables)
Equip with start control box or digital auto-control box.
NEMA dimension standards.
Curve tolerance according to ISO 9906.
Options on request
Special mechanical seal.
Other voltages or frequency 60 Hz.